Specifications

Frequency range UHF (band IV/V) 470 MHz to 862 MHz
  VHF (band III) 170 MHz to 255 MHz
Available standards analog TV B/G, D/K, M, M1, N, I, I1
digital TV DVB-T, DVB-H, ATSC, ATSC Mobile DTV, MediaFLO™
digital audio broadcasting DAB, DAB+, T-DMB
Power supply AC 100 V to 240 V ± 10 %, 47 Hz to 63 Hz
Synchronization
Reference frequency   10 MHz, –5 dBm to +20 dBm or LVT, BNC
Reference pulse   1 pps (1 Hz, TTL, BNC)
Operation
Display, keypad and status LEDs   local operation and display,
200 × 48 pixel color display
Ethernet interface, RJ-45   convenient local or remote control via standard web browser
Parallel remote control interface optional floating contacts for messages and commands
Environmental conditions
Max. installation height   2000 m above sea level
(>2000 m on request)
Operating temperature range   +1 °C to +45 °C
Relative humidity (max.)   95 %, non-condensing
Electromagnetic immunity
To fast transients/bursts in line with
IEC 61000‑4‑4
  < 2 kV (power feed)
< 1 kV (signal inputs)
To surges in line with
IEC 61000-4-5
  symmetrical < 1 kV (e.g. L1-L2, L-N)
unsymmetrical < 2 kV (e.g. L-PE, N-PE)
If a higher electromagnetic immunity is required for transmitter operation, appropriate protective measures must be taken. Rohde & Schwarz offers appropriate options for overvoltage and lightning protection.
RF output R&S®SCV8x01x, R&S®SCW8x01x, R&S®SCA8x01x N
R&S®SCV8x02x 7/16
Dimensions (W × H × D) R&S®SCV8x01Ex, R&S®SCW8x01Ex, R&S®SCA8x01Ex 483 mm (19") × 4 HU × 550 mm
(19 in × 4 HU × 21.7 in)
R&S®SCV8x02Ex 483 mm (19") × 7 HU × 550 mm
(19 in × 7 HU × 21.7 in)
 

Important: To comply with the applicable standards and limit values for the suppression of out-of-band emissions (and in the case of digital standards, also for maintaining the required shoulder distance), the transmitter may only be operated with suitable filters at the RF output.