Configured as R&S® NV8602 NV8603 NV8604 NV8605 NV8606 NV8608 NV8610 NV8612 NV8616 NV8620
Number of R&S®VH8600A1
amplifiers
2 3 4 5 6 8 10 12 16 20
Output power (RMS)
for COFDM standards 1) 2) 3)
1.3 kW 1.9 kW 2.6 kW 3.1 kW 3.7 kW 5.0 kW 6.1 kW 7.2 kW 9.7 kW 11.8 kW
RF output for COFDM standards EIA 1 5/8" EIA 3 1/8"
Output power (RMS)
for ATSC/ATSC Mobile DTV 1) 2) 4)
1.8 kW 2.7 kW 3.6 kW 4.4 kW 5.2 kW 7.0 kW 8.5 kW 10.1 kW 13.6 kW 16.5 kW
RF output for ATSC/ATSC Mobile DTV EIA 1 5/8" EIA 3 1/8" EIA 4  1/2"
Dimensions
(H × W × D)
2000 mm × 600 mm × 1100 mm
(78.7 in × 23.6 in × 43.3 in)
2000 mm × 1200 mm ×  1100  mm
(78.7 in × 47.2 in × 43.3 in)

1) Before bandpass filter.

2) With AC power supply of 3 × 400 V AC.

3) Average output power; at < 510 MHz, power reduced by approx. 10 %; at > 662 MHz, power increased by approx. 5 %.

4) Average output power; at < 510 MHz, power reduced by approx. 5 %; at > 662 MHz, power increased by approx. 6 %.

 

Specifications
Digital TV
TV standards   DVB-T, DVB-T2, DVB-H, ISDB-T, ISDB-TB, DTMB, MediaFLO, ATSC, ATSC Mobile DTV,
Inputs   4 × BNC, 75 Ω
  DVB-T2 2 × BNC, 75 Ω and 2 × RJ-45
Analog TV
TV standards   B/G, D/K, M, M1, N, I, I1
Color transmission   PAL, NTSC, SECAM
Sound transmission   dual-sound coding in line with IRT or FM single sound and NICAM728
(−13  dB/−20  dB) or
FM single sound (−10 dB)
Inputs   2 × video (BNC, 75 Ω), 2 × audio
(XLR, 3-contact)
General data
Frequency range UHF bands IV/V 470 MHz to 862 MHz
Power supply with three-phase amplifiers (standard) 3 × 400 V ± 15 % 1),
47 Hz to 63 Hz
with single-phase amplifiers (optional, for R&S®NV8602 to R&S®NV8610) 3 × 208 V – 10 %/+ 15 % 1) or
240 V – 15 %/+ 10 % 2)
47 Hz to 63 Hz
Max. installation altitude   2000 m above sea level
(> 2000  m on request)
Operating temperature range   +1 °C to +45 °C
Relative humidity (max.)   95 %, non-condensing
Immunity 3) to fast transients and burst in line with IEC  61000-4-4 < 4 kV (AC supply),
< 1 kV (signal inputs)
to surges in line with
IEC  61000-4-5
balanced < 2 kV (e.g. L1-L2)
unbalanced < 4 kV (e.g. L1-N)
Synchronization
Reference frequency   10 MHz, 0.1 V to 5 V (Vpp) or TTL, BNC
Reference pulse   1 Hz, TTL, BNC
Operation
Display, keypad and status LEDs   local operation and display
Ethernet interface, RJ-45   convenient operation, local or remote, via standard web browser
optional network management interface via SNMP
Parallel remote-control interface optional floating contacts for messages and commands
1) To be connected to an AC supply network with Y, 3w + N + PE.
2) To be connected to an AC supply network with 120/240 V, 2w + N + PE.
3) With integrated AC supply overvoltage protection; more stringent requirements must be covered by additional on-site measures.

To comply with the applicable standards and limit values for the suppression of out-of-band emissions (and in the case of digital standards, also for maintaining the required shoulder distance), the transmitter may only be operated with suitable filters at the RF output.