Specifications

RF data    
Frequency range base unit 9 kHz to 3.5. GHz
  with R&S®EM100-FE option 9 kHz to 7.5 GHz
RF input    
Input level for linear operation 9 kHz to 30 MHz typ. –13 dBm/94 dBµV
  20 MHz to 3.5 GHz
(attenuator on)
typ. 0 dBm/107 dBµV

3.5 GHz to 7.5 GHz typ. –24 dBm/83 dBµV
Impedance   50 Ω
VSWR 9 kHz to 3.5 GHz ≤ 2:1
  3.5 GHz to 7.5 GHz ≤ 3:1
Input attenuation 20 MHz to 3.5 GHz typ. 10 dB, eff. 25 dB
(can be switched manually)
Preselection 9 kHz to 30 MHz 30 MHz lowpass filter
  20 MHz to 1.5 GHz tuned bandpass filters
  1.5 GHz to 7.5 GHz highpass/lowpass filter
combination
Noise figure, DANL    
Noise figure
(demodulation path)
100 kHz typ. 16 dB
  1 MHz typ. 13 dB
  11 MHz typ. 13 dB
  19 MHz typ. 14 dB
  50 MHz (attenuator off) typ. 8 dB
  140 MHz (attenuator off) typ. 8 dB
  430 MHz (attenuator off) typ. 8 dB
  1.1 GHz (attenuator off) typ. 10 dB

1.5 GHz (attenuator off) typ. 8 dB
  3.4 GHz (attenuator off) typ. 12 dB
  3.6 GHz typ. 15 dB
  5.5 GHz typ. 16 dB
  7.499 GHz typ. 20 dB
     
Immunity to interference,
nonlinearity
   
Third-order intercept
(TOI) (input)
at ≥ 300 kHz test signal offset  
   Test level –20 dBm 9 kHz to 30 MHz  typ. 22 dBm
   Test level –35 dBm 20 MHz to 600 MHz
(attenuator off)
 typ. –11 dBm
   Test level –35 dBm 600 MHz to 2.6 GHz
(attenuator off)
 typ. –7 dBm
   Test level –35 dBm 2.6 GHz to 3.5 GHz
(attenuator off)
 typ. –3 dBm
   Test level –10 dBm 20 MHz to 3.5 GHz
(attenuator on)
 typ. 20 dBm
   Test level –30 dBm 3.5 GHz to 7.5 GHz  typ. –3 dBm
IF data    
IF spectrum display range   1kHz to 10 MHz,
1/2/5/10/20/50/100/
200/500 kHz,1/2/5/10 MHz
Display modus   Normal (ClearWrite), Average,
MaxHold, MinHold
IF demodulation bandwidths 15 filters (specified values indicate
3 dB bandwidths)
150/300/600 Hz
1.5/2.4/6/9/15/30/50/
120/150/250/300/500 kHz
Demodulation modes all demodulation bandwidths AM, FM, PULSE, I/Q
  demodulation bandwidths ≤ 9 kHz USB,CW
  demodulation bandwidths ≤ 9 kHz LSB
  demodulation bandwidths ≤ 15 kHz ISB
  demodulation bandwidths ≤ 9 kHz CW
Scan modes    
Frequency scan (FScan) start and stop frequency,
step width
user-selectable
  scan speed up to 150 channels/s
Memory scan (MScan) memory locations 1024, user-programmable
  scan speed up to 150 channels/s
Panorama scan (PScan) start and stop frequency user-selectable
  resolution bandwidths
(bin widths)
125/250/500/625 Hz
1.25 /2.5/3.125/6.25/
12.5/25/50/100 kHz
  scan speed up to 1.8 GHz/s
  (RBW = 100 kHz, measurement  time = 500 µs, RF spectrum = Normal/ClearWrite, display mode = RF spectrum)