R&S®TS712x Shielded RF Test Chambers

Reliable RF tests on devices with radio interface

Specifications

  R&S TS7121 R&S TS7123
 
Interfaces
Compressed air (grease-free) 4 bar to 8 bar (automatic version only)
Control of pneumatic system 25-contract D-Sub (m), 24 V, optionally USB control
Exchangeable connector plate yes
Filter feedthroughs 25-contract D-Sub (f)
9-contract D-Sub (f)
RF shielding effectiveness1)
300 MHz to 14 GHz typ. >35 dB typ. >40 dB
500 MHz to 3 GHz typ. >70 dB typ. >60 dB
1 GHz to 2.5 GHz, 2.5 GHz to 4 GHz typ. >75 dB, typ. >60 dB typ. >60 dB, typ. >50 dB
Options
Antenna coupler GSM / WCDMA / CDMA2000®, Bluetooth®, WLAN, ISM, coupling factor typ. 10 dB to 20 dB2)
Elevated cover yes
Absorbent material yes
USB 2.0 filter feedtrough yes
Temperature Ranges
Operating temperature range +10 °C to +40 °C
Storage temperature range -20 °C to +60 °C
Relative humidity
Operation 90 % r.h., non-condensating at +10 °C to +30 °C
75 % r.h., non-condensating at +10 °C to +40 °C
Storage 90 % r.h., non-condensating at up to +60 °C
Dimensions (W x H x D)
Outer dimensions (slide-in unit closed)3)
Automatic version4)
Manual version with handle
 
155 x 305 x 428 mm ( 6.1 " x 12 " x 16.8 ")
155 x 305 x 498 mm ( 6.1 " x 12 " x 19.6 ")
 
155 x 305 x 428 mm ( 6.1 " x 12 " x 16.8 ")
155 x 305 x 498 mm ( 6.1 " x 12 " x 19.6 ")
Additional depth with slide-in unit fully extended + 210 mm (+ 8.26 ") + 248 mm (+ 9.76 ")
Inner dimensions including absobent material 87 mm x 130 mm x 354 mm (3.4 " x 5.1 " x 13.9 ") 250 mm x 170 mm x 345 mm (9.8 " x 6.7 " x 13.5 ")
Max. DUT dimensions including DUT mount 80 mm x 130 mm x 194 mm (3.1 " x 5.1 " x 7.6 ") 245 mm x 165 mm x 230 mm (9.6 " x 6.5 " x 9 ")
Weight
with absorbent material, without antenna approx. 25 kg approx. 35 kg
 
1) With absorbent material, without external cables.
2) E.g. for GSM antenna module.
3) Without connectors on rear panel (>20 mm), without lateral clamping levers (2 × 30 mm).
4) Use only in protected environment; risk of bodily injury through automatic opening and closing of RF chamber (see safety sheet included with R&S TS712x documentation).